Views
No views yet
SentenceTransformer(
(0): Transformer({'max_seq_length': 8192, 'do_lower_case': False}) with Transformer model: XLMRobertaModel
(1): Pooling({'word_embedding_dimension': 1024, 'pooling_mode_cls_token': True, 'pooling_mode_mean_tokens': False, 'pooling_mode_max_tokens': False, 'pooling_mode_mean_sqrt_len_tokens': False, 'pooling_mode_weightedmean_tokens': False, 'pooling_mode_lasttoken': False, 'include_prompt': True})
(2): Normalize()
)pip install -U sentence-transformers1from sentence_transformers import SentenceTransformer
2
3# Download from the 🤗 Hub
4model = SentenceTransformer("naucica77/bge-m3-finetuned-NSfault")
5# Run inference
6sentences = [
7 'What is the primary purpose of IPC (Inter Processor Communication) within a system?',
8 '3장 IPC 장애처리 \n \n \n \nIPC 개요 \n \nIPC(Inter Processor Communication) 는 노드 내에 있는 프로세서 간의 통신을 \n의미한다 . \n시스템에서 IPC 를 위한 각 노드 간의 연결은 다음 그림과 같다. \n \n그림 1. 시스템 구성 노드 간 관계 \n \nVOMA0 \n VOMA1 \n \n \nVIDA0 \n VIDA1 ● ● ● ● ● VSA0 \n VISA1 \n \n \nVECA0 \n VECA1 ● ● ● ● ● \n \n \n시스템에서는 모든 노드 사이에 대한 IPC 진단이 이루어진다 . \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \nSPSC4000 알람 및 장애처리 매뉴얼 SVSCR 1.0.0 v1.0 8 \n© Samsung Proprietary and Confidential',
9 '1 장 유지보수 개요 \n \n장애, 가입자 서비스의 이상과 같은 상황에서 발생하는 장애이다 . Major \n알람 발생 시에도 운용자의 즉각적인 조치가 필요하다 . \n \nMinor 알람: Minor 알람은 Critical 알람이나 Major 알람에 비하여 시스템에 \n미치는 영향이 적은 장애이다 . \n \nCATE(Category) \n \n시스템에서 발생하는 알람은 알람은 ITU-T X.733 에 의해 다음과 \n같은 범주(Category)로 분류할 수 있다. \n \nCOMM: Communications alarm type, 한 지점에서 다른 지점으로 정보를 \n전달하기 위한 절차/처리에 관련된 알람 \nQOS: Quality of service alarm type, 서비스 품질의 저하와 관련된 알람 \n \nPROC: Processing error alarm type, SW 나 Processing 오류 발생과 \n관련된 알람 \nEQUIP: Equipment alarm type, 설치된 장비의 오류 발생과 관련된 알람 \nENV: Environmental alarm type, 시스템의 장비의 환경 상태와 관련된 알람 \n \nCOLUMN( 하위 Category) \n \nCategory 의 하위의 범주를 이용하여 알람을 세분화하여 관리하는 구분 기준이다 . \n \nSUPP: Suppression 알람 \nBLK: Block 장애 관련 알람 \nCARD: 시스템 노드 장애 관련 알람 \n \nLINK: 시스템 연동 링크 장애 관련 알람 \nENVIR: 시스템 환경 장애 관련 알람 \nSYS: System 기능 장애 관련 알람 \nOVLD: 부하 관련 알람 \n \nRSC: 시스템 내부 자원 관련 알람 \nIODEV: 디스크 장애 관련 알람 \nNE: 연동 Network Element 장애 알람 \n \nNTP: 시각 관리 장애 알람 \nOOS: 서비스 장애 알람 \n \n표 1. 알람 종류 \n CODE GRD CATE COLUMN DESCRIPTION \n 0140 MIN PROC SUPP FAULT SUPPRESSION ALARM \n \n \n SPSC4000 알람 및 장애처리 매뉴얼 SVSCR 1.0.0 v1.0 2 \n © Samsung Proprietary and Confidential',
10]
11embeddings = model.encode(sentences)
12print(embeddings.shape)
13# [3, 1024]
14
15# Get the similarity scores for the embeddings
16similarities = model.similarity(embeddings, embeddings)
17print(similarities.shape)
18# [3, 3]sentence_0 and sentence_1| sentence_0 | sentence_1 | |
|---|---|---|
| type | string | string |
| details |
|
|
| sentence_0 | sentence_1 |
|---|---|
What should be verified after performing the corrective actions to resolve a CCF GROUP ACCESS FAIL ALARM? | 부록 C 알람 코드별 장애처리 [object Object] [object Object] 2593 CCF GROUP ACCESS FAIL ALARM [object Object] [object Object] 번호 2593 DESCRIPTION CCF GROUP ACCESS FAIL ALARM [object Object] [object Object] 등급 CRI NAME CCF_GRP_ACC_F [object Object] [object Object] Category COMM Column NE [object Object] [object Object] 메시지 내역 *** A2593 CCF GROUP ACCESS FAIL ALARM [object Object] LOC = aaaa [object Object] ### A2593 CCF GROUP ACCESS FAIL ALARM CLEARED [object Object] LOC = aaaa [object Object] ALM_ON= bbbb [object Object] [설명] [object Object] aaaa: 장애가 발생한 NE 그룹 정보 [object Object] bbbb: 알람이 발생했던 시간 [object Object] [예] [object Object] *** A2593 CCF GROUP ACCESS FAIL ALARM [object Object] LOC = CCF _GRP0 [object Object] [object Object] 원인 해당 CCF 그룹에 속한 모든 CCF 와 접속이 해제되는 경우 발생한다 . [object Object] [object Object] 조치방법 해당 CCF 그룹에 속한 CCF 의 접속 상태를 확인하고 , 접속이 해제되어 있으면 연결한다 . [object Object] RTRV-NE-STS 명령어를 실행하여 해당 CCF 와의 접속 상태를 확인한다 . [object Object] [참고] RTRV-NE-STS 명령어 사용 예 및 확인 사항 [object Object] [명령어 사용 예] [object Object] 1 OOS(Out Of Service) 상태의 CCF 시스템의 접속 상태를 조회하는 경우 [object Object] RTRV-NE-STS:NETYPE= CCF,STS=OOS; [object Object] 2 전체 등록된 CCF 시스템의 접속 상태를 조회하는 경우 [object Object] RTRV-NE-STS:NETYPE= CCF; [object Object] [확인 사항] [object Object] 조치 방법 수행 후 명령어 결과의 STS 상태가 INS(In -service) 상태인지 확인한다 . ... |
What is the typical cause for the "NE EVENT OVER LIMIT FAULT" with fault code 7007 in a telecommunications network node? | 부록 D 폴트 코드별 장애처리 [object Object] [object Object]7007 NE EVENT OVER LIMIT FAULT [object Object] [object Object]번호 7007 DESCRIPTION NE EVENT OVER LIMIT FAULT [object Object] [object Object]메시지 내역 F7007 NE EVENT OVER LIMIT FAULT [object Object] LOC = aaaa [object Object] INF = bbbb [object Object]COUNT = cccc [object Object][설명] [object Object]aaaa: 장애가 발생한 노드 정보 [object Object]bbbb: 장애가 발생한 상세 정보 [object Object]cccc: 장애 발생 사유 [object Object][예] [object Object]F7007 NE EVENT OVER LIMIT FAULT [object Object]LOC = VIDA0 [object Object]INF = HSS_ID1 -ULR [object Object]COUNT = 1234(LIMIT:1000/SEC) [object Object]; [object Object]원인 지정된 INTERVAL 내에 전송할 수 있는 최대값 메시지를 보낸 순간부터 해당 폴트가 발생한다 . [object Object]메시지를 전송 할 수 있는 최대값은 CSSM(Call Session Module) 별로 제어가 된다 [object Object]System PNA 서버(Presence Network Agent) 의 경우에는 Limit 에 의해 연동이 되지 않는 경우 호 [object Object]Impact 실패가 발생할 수 있다. 그 외 NE 들도 각각 NE 와 해당 메시지가 전달되지 않음으로 [object Object]호 장애가 발생 할 수 있다. [object Object]조치방법 해당 NE 의 상태를 확인하거나 CHG-NEEC-INF 명령어를 통해 최대값을 조정한다 . [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object] [object Object]SPSC4000 알람 및 장애처리 매뉴얼 SVSCR 1.0.0 v1.0 96 [object Object]© Samsung Proprietary and Confidential |
What is the likely system impact if an MGC Access Fail Alarm occurs and the MGC server is not accessible? | 부록 C 알람 코드별 장애처리 [object Object] [object Object] 2582 MGC ACCESS FAIL ALARM [object Object] [object Object] 번호 2582 DESCRIPTION MGC ACCESS FAIL ALARM [object Object] [object Object] 등급 MAJ NAME MGC_ACC_F [object Object] [object Object] Category COMM Column NE [object Object] [object Object] 메시지 내역 ** A2582 MGC ACCESS FAIL ALARM [object Object] LOC = aaaa [object Object] INF = bbbb [object Object] ## A2582 MGC ACCESS FAIL ALARM CLEARED [object Object] LOC = aaaa [object Object] INF = bbbb [object Object] ALM_ON= cccc [object Object] [설명] [object Object] aaaa: 장애가 발생한 NE 정보 [object Object] bbbb: 장애가 발생한 NE 의 IP 주소 [object Object] cccc: 알람이 발생했던 시간 [object Object] [예] [object Object] ** A2582 MGC ACCESS FAIL ALARM [object Object] LOC = MGC_ID4 [object Object] INF = 10.254.192.215 [object Object] [object Object] 원인 MGC 와 접속이 해제되는 경우 발생한다 . [object Object] [object Object] 조치방법 1 해당 MGC 의 접속 상태를 확인하고 , 접속이 해제되어 있으면 연결한다 . [object Object] 2 RTRV-NE-STS 명령어를 실행하여 해당 MGC 와의 접속 상태를 확인한다 . [object Object] [참고] RTRV-NE-STS 명령어 사용 예 및 확인 사항 [object Object] [명령어 사용 예] [object Object] 1 OOS(Out Of Service) 상태의 MGC 시스템의 접속 상태를 조회하는 경우 [object Object] RTRV-NE-STS:NETYPE= MGC,STS=OOS; [object Object] 2 전체 등록된 IBCF 시스템의 접속 상태를 조회하는 경우 [object Object] RTRV-NE-STS:NETYPE= MGC; [object Object] [확인 사항] [object Object] 조치 방법 수행 후 명령어 결과의 STS 상태가 INS(In -service) 상... |
MultipleNegativesRankingLoss with these parameters:
1{
2 "scale": 20.0,
3 "similarity_fct": "cos_sim"
4}per_device_train_batch_size: 4per_device_eval_batch_size: 4num_train_epochs: 2multi_dataset_batch_sampler: round_robinoverwrite_output_dir: Falsedo_predict: Falseeval_strategy: noprediction_loss_only: Trueper_device_train_batch_size: 4per_device_eval_batch_size: 4per_gpu_train_batch_size: Noneper_gpu_eval_batch_size: Nonegradient_accumulation_steps: 1eval_accumulation_steps: Nonetorch_empty_cache_steps: Nonelearning_rate: 5e-05weight_decay: 0.0adam_beta1: 0.9adam_beta2: 0.999adam_epsilon: 1e-08max_grad_norm: 1num_train_epochs: 2max_steps: -1lr_scheduler_type: linearlr_scheduler_kwargs: {}warmup_ratio: 0.0warmup_steps: 0log_level: passivelog_level_replica: warninglog_on_each_node: Truelogging_nan_inf_filter: Truesave_safetensors: Truesave_on_each_node: Falsesave_only_model: Falserestore_callback_states_from_checkpoint: Falseno_cuda: Falseuse_cpu: Falseuse_mps_device: Falseseed: 42data_seed: Nonejit_mode_eval: Falsebf16: Falsefp16: Falsefp16_opt_level: O1half_precision_backend: autobf16_full_eval: Falsefp16_full_eval: Falsetf32: Nonelocal_rank: 0ddp_backend: Nonetpu_num_cores: Nonetpu_metrics_debug: Falsedebug: []dataloader_drop_last: Falsedataloader_num_workers: 0dataloader_prefetch_factor: Nonepast_index: -1disable_tqdm: Falseremove_unused_columns: Truelabel_names: Noneload_best_model_at_end: Falseignore_data_skip: Falsefsdp: []fsdp_min_num_params: 0fsdp_config: {'min_num_params': 0, 'xla': False, 'xla_fsdp_v2': False, 'xla_fsdp_grad_ckpt': False}fsdp_transformer_layer_cls_to_wrap: Noneaccelerator_config: {'split_batches': False, 'dispatch_batches': None, 'even_batches': True, 'use_seedable_sampler': True, 'non_blocking': False, 'gradient_accumulation_kwargs': None}parallelism_config: Nonedeepspeed: Nonelabel_smoothing_factor: 0.0optim: adamw_torch_fusedoptim_args: Noneadafactor: Falsegroup_by_length: Falselength_column_name: lengthproject: huggingfacetrackio_space_id: trackioddp_find_unused_parameters: Noneddp_bucket_cap_mb: Noneddp_broadcast_buffers: Falsedataloader_pin_memory: Truedataloader_persistent_workers: Falseskip_memory_metrics: Trueuse_legacy_prediction_loop: Falsepush_to_hub: Falseresume_from_checkpoint: Nonehub_model_id: Nonehub_strategy: every_savehub_private_repo: Nonehub_always_push: Falsehub_revision: Nonegradient_checkpointing: Falsegradient_checkpointing_kwargs: Noneinclude_inputs_for_metrics: Falseinclude_for_metrics: []eval_do_concat_batches: Truefp16_backend: autopush_to_hub_model_id: Nonepush_to_hub_organization: Nonemp_parameters:auto_find_batch_size: Falsefull_determinism: Falsetorchdynamo: Noneray_scope: lastddp_timeout: 1800torch_compile: Falsetorch_compile_backend: Nonetorch_compile_mode: Noneinclude_tokens_per_second: Falseinclude_num_input_tokens_seen: noneftune_noise_alpha: Noneoptim_target_modules: Nonebatch_eval_metrics: Falseeval_on_start: Falseuse_liger_kernel: Falseliger_kernel_config: Noneeval_use_gather_object: Falseaverage_tokens_across_devices: Trueprompts: Nonebatch_sampler: batch_samplermulti_dataset_batch_sampler: round_robin1@inproceedings{reimers-2019-sentence-bert,
2 title = "Sentence-BERT: Sentence Embeddings using Siamese BERT-Networks",
3 author = "Reimers, Nils and Gurevych, Iryna",
4 booktitle = "Proceedings of the 2019 Conference on Empirical Methods in Natural Language Processing",
5 month = "11",
6 year = "2019",
7 publisher = "Association for Computational Linguistics",
8 url = "https://arxiv.org/abs/1908.10084",
9}1@misc{henderson2017efficient,
2 title={Efficient Natural Language Response Suggestion for Smart Reply},
3 author={Matthew Henderson and Rami Al-Rfou and Brian Strope and Yun-hsuan Sung and Laszlo Lukacs and Ruiqi Guo and Sanjiv Kumar and Balint Miklos and Ray Kurzweil},
4 year={2017},
5 eprint={1705.00652},
6 archivePrefix={arXiv},
7 primaryClass={cs.CL}
8}