Machina CWRU Enhanced Bearing Classifier
This experimental plugin uses 21 time-domain, spectral, and envelope features
from 4,096-sample vibration windows and a sigmoid-calibrated ExtraTrees
classifier. Training used
64 12 kHz drive-end files from the public Case Western Reserve University
bearing benchmark, with source-file grouping and leave-one-RPM-out checks.
The benchmark is useful for reproducibility, but it is not evidence of
generalization to customer machinery. The reported score is a research
benchmark only; validate on target assets and operating regimes before use.
The classifier abstains below its configured confidence threshold.